3000 × 2000 px. Open it full size to see it at 100%.

What the engines say

1 · Sway under wind
2 · Where the load goes
3 · First three vibration modes
4 · What the ground has to take
5 · Two engines
6 · Mesh check
7 · Shown in Revit
8 · The curl root

Blender Cycles renders through the Archi Automate MCP, unretouched, no image model; Python diagrams made outside Archi Automate. PyNite computed the values shown in Revit (JP-BSL allowable stress). The images show sway, forces, vibration modes, support reactions, solver agreement, mesh sensitivity and the curl-root revision. Preliminary study with PyNite and our own solver; not an engineering design. F1 failed the fit check; F2 is a junction fit, not yet analysed. Detailed reading notes follow below.

Simulations

Ember Monolith · Structural check

From the modelFrame model → PyNite + own solver

Under self-weight, snow and wind, the timber frame F1 reaches 0.597 of the allowable stress, and 0.650 in shear and torsion, against a limit of 0.80, both in a rib at the entrance. Its sideways movement comes closest to its limit at the base of the wall: 14.4 mm against 15.0 mm. Two independent engines, PyNite and our own solver, agree on every compared value within 2 %.

Good for an early read: whether a timber frame can live inside the wall, and where it is tightest, which is the sway. It does not yet tell you the frame can be built: a check against the real wall solid failed at the curl root, so F1 is being replaced, and buckling, second-order effects, connections and foundations are open.

Ask your AI assistant

Check the timber frame in PyNite and a second solver, then show its utilisation in Revit and Blender.

Show the full prompt

Using the Archi Automate MCP, take the frame [F1] and, in Python outside Archi Automate, run it in [PyNite] and in a second, independent solver under [self-weight, snow and wind]. Check timber stress, shear and torsion against [Japanese allowable-stress] limits, member deflection, and sway against [the drift limit]; compare the two engines on every governing value within [2 %], and repeat the run with every element halved. Then check the members at [the curl root] against the real wall solid in the open Rhino document, read-only. Show the utilisation on the native Revit model as a coloured 3D view with a legend that names the engine, render a utilisation map in Blender, and draw the deformed shape, the forces, the modes, the reactions and the two checks from the results.

Not a transcript. The check was run in one working session by AI agents, directed in conversation; this task restates it. Revit and Blender display the results; neither computed them. Values in [brackets] are yours to change.

A structural check of the timber frame inside the wall of an invented temple, run in Python outside Archi Automate with PyNite and our own solver, shown in Revit. Preliminary: the frame passes the stress and movement checks but failed a fit check against the wall solid; F2 is being prepared.

Archi sample model: an invented building on a real site in Shikoku, Japan. Not a built project.

Engine
Claude (orchestration, checks and graphics). Structural numbers: PyNite 3.2.1 and our own solver. No image or video model.
Input
PyNite
Date
2026-11-22
Tools
PyNite → Revit → Blender → Rhino → rhino_run_readonly_csharp_probe → blender_run_write_task → blender_run_readonly_python_probe → revit_run_write_task
MCP calls
rhino_run_readonly_csharp_probe → revit_run_write_task → blender_run_write_task

Method notes

Preliminary study with PyNite and our own solver; not an engineering design. The main image is the utilisation map of the timber frame inside the wall of the Ember Monolith, an invented temple: the far half of the frame seen from inside, each member coloured by its share of the allowable stress. The values are computed by PyNite (JP-BSL allowable stress), shown in Revit and Blender.

What was checked. Each member’s stress, and its shear and torsion, against the allowable stress; how far each member bends; how far the wall moves sideways; and that no member leaves the wall or runs into another. Loads are self-weight, snow and wind on a Japanese allowable-stress basis. The rules were written down before the run, and the two engines had to agree before any result counted.

The curl root. A check of the members around the root of the curled entrance wall against the real wall solid in Rhino, read-only through the Archi Automate MCP, found three members inside the wall but short of the cladding allowance. F1 passes the stress and movement checks; the fit at the curl root failed the solid check, so F2 is being prepared.

Shown in Revit and Blender. The values were written onto the native Revit model and shown in a coloured 3D view, with a legend that says they come from PyNite and that Revit did not compute them. The main map is a Blender render, made through the Archi Automate MCP, with its labels and legend drawn over it; the other result images are diagrams drawn with Python from the same results.

Done outside Archi Automate. PyNite 3.2.1, our own second solver, the checks and the diagrams are Python scripts that AI agents wrote and ran outside the product.

Not checked yet. Second-order effects and buckling, radial tension in the curved ribs, connections (concepts, not designed), foundations (assumed, not designed), fire and code compliance. No engineer has reviewed this.

Reading the figures. Diagrams 1 and 2 show half the frame, braces not drawn. 1: the sway limit is height / 200 and at least 15 mm; closest to its limit is 14.4 mm against 15.0 mm (96 %), at the wall base; the largest sway is 33.9 mm at 11.4 m height, against a limit there of 57.0 mm. 2: the colour scale is symmetric about zero. 4: each arrow is the largest reaction over the strength combinations, on one scale with a 100 kN legend arrow; 50 of the 79 supports see some uplift; the footing line is labelled assumed, not designed. 5: each dot is the least-agreeing value of one quantity in one load combination, plus the three periods and the total mass; the largest difference is 2.7e-5 %, and 0 of the 5,960,988 compared values fall outside the 2 % band. 8: the foot of the stout rib (320 x 500) is 2 mm from the soffit under the overhang, and the two purlin ends beside it (120 x 360, at 3.0 m and 1.5 m) are 38 mm from the outer wall face; the other 62 junction members passed. On the right, F2’s answer, still in progress: the leg and the rib foot become one glulam piece 200 x 540, turned 90 degrees and moved 249 mm, which keeps at least 176 mm from the wall surface; the purlin ends, now joined to the leg, keep 137 mm, and the unchanged stout rib above keeps 115 mm. F2 is so far a junction fit, not yet analysed. Hatched: the 100 mm cladding zone in the section plane.

More cases

All cases

Full size view