How the frame was found
Ember Monolith · Structure search
From the modelRhino → PyNite, 15 variants + 1
Ask your AI assistant
Search for a timber frame inside the 0.8 m wall, round by round, and rank the passing ones by carbon.
Show the full prompt
Using the Archi Automate MCP, read the wall of the Rhino model [Ember Monolith] read-only: the [generating profiles], the slot edge, the entrance and the curl, and write them to a frozen dataset without changing or saving the document. Then, in Python outside Archi Automate, generate structural variants that fit inside the [0.8 m] wall without touching the shell, the curled entrance wall or the open slot: [glulam ribs, steel ribs, rings and braces]. Run each in [PyNite] and cross-check it with a second, independent solver; check stress, shear, deflection and sway against [Japanese allowable-stress] limits; rank the passing ones by [upfront carbon, A1-A3]. Fix each round's rules before it runs, and keep going round by round until a variant passes. Then render the frame of each round from one camera in Blender.
AI agents searched for a timber frame inside the 0.8 m wall of an invented temple: 15 variants over three rounds and one comparison run, checked in PyNite and our own solver. Preliminary: F1 passed the stress and movement checks, then failed a fit check at the curl root; F2 is being prepared.
- Engine
- Claude (orchestration, checks and graphics), Fable 5.2 (structure lead), gpt-6.1-sol through Codex (reviews). Structural numbers: PyNite 3.2.1 and our own solver. No image or video model.
- Input
- Rhino
- Date
- 2026-11-22
- Tools
- Rhino → PyNite → Blender → rhino_run_readonly_csharp_probe → blender_run_write_task
- MCP calls
- rhino_run_readonly_csharp_probe → blender_run_write_task
Method notes
Preliminary study with PyNite and our own solver; not an engineering design. The Ember Monolith is an invented temple with a sculpted wall 0.8 m thick. This page shows how AI agents looked for a structure that fits inside that wall, with the shell, the curled entrance wall and the open rooflight slot left exactly as designed. The main image, a Blender render, shows the frame of each round from one camera.
The brief. The owner asked for a wood or steel structure inside the wall, chose the lowest upfront carbon as the aim, and allowed free tools only. Each round’s rules were fixed before it ran; the one rule changed afterwards, on the movement of the open slot, was changed by the owner, and that movement is now reported rather than checked.
Three rounds. The agents checked 15 variants over three rounds, plus one comparison run. In the first round, the worst value of each variant ran from 3.66 to 28.64 times its limit; in the second, from 1.61 to 2.46. In the final round one variant, F1, passed every gated check, at 0.96 of its limit (sway, 14.4 mm against 15.0 mm); the other two did not: H3F at 1.20 and H4F at 1.13.
Carbon. F1’s upfront carbon (product stage, A1-A3) is 239.6 t CO2e, or 74 %, lower than that of the steel-rib model HS. That is against that particular steel model, not against an optimised steel frame, which nobody looked for. Carbon stored in the timber is reported apart and never subtracted.
Where it stands. F1 passes the stress and movement checks; the fit at the curl root failed the solid check, so F2 is being prepared. Buckling, second-order effects, connections and foundations are still open.
Done outside Archi Automate. Through the Archi Automate MCP, an agent read the wall from the open Rhino model with rhino_run_readonly_csharp_probe, read-only, and left the document unchanged; another rendered the main image in Blender with blender_run_write_task. The generator, the two engines (PyNite 3.2.1 and our own solver), the checks, the ranking, the two charts and the section are Python that AI agents wrote and ran outside the product.
Reading the charts and the section. Chart 1 is on a log scale (1 = at the limit): round 1 compared six layouts with coarse, uniform starting sizes, all governed by horizontal sway; round 1b tested six refined frames, each governed by the change in width of the open roof slot, as then required; H3F and H4F are round 1b’s H3 and H4, rerun under the final rules. The slot-width rule (21 mm) was required in rounds 1 and 1b, which are shown as computed then; before the final round the owner made it report-only, because nothing spans the open slot. It was the only check the steel model HS failed in round 1b. Not drawn: G-strut, a round 1 comparison run that was never ranked (12.5, next to G1). Chart 2 shows one point for each of the 16 variants with a quantities file; some coincide, so 12 positions show (H3/H3F and H4/H4F differ by under 1 kg, G-strut sits on G1, H1 and H5 nearly coincide). Carbon covers the product stage (A1-A3, fossil) of the parts in the ranking, with their connector allowance, and mass covers the same parts; foundations, cladding, transport and erection, use and end of life are excluded, and stored biogenic carbon is reported, never subtracted. Circles have glulam ribs and squares steel ribs; filled points passed the gate, hollow ones did not. The points with less carbon than F1 all failed checks: H3/H3F (72.6 t), G2 (83.0 t) and H2 (84.2 t). HS is the steel model we compared against, not an optimised steel frame. Drawing 3 is a Python vector drawing, not a render: purlin rings 0.12 x 0.36 m and braces 0.12 x 0.12 m are cut, and the rib beyond, 0.28 x 0.54 m on one side and 0.20 x 0.54 m on the other, fills the 0.60 m zone with a few centimetres to spare. That clearance describes this cut only; it does not show that F1 fits throughout, and the fit check at the curl root failed.