3000 × 2000 px. Open it full size to see it at 100%.

How the frame was found

1 · Worst check against its limit, round by round
2 · Upfront carbon against structure mass
3 · The frame inside the wall

Blender Cycles renders through the Archi Automate MCP, unretouched, no image model; charts and section drawn in Python outside Archi Automate. Charts show the search rounds and product-stage carbon against mass; the section cuts across the wall and shows the frame in its 0.60 m zone. Preliminary study with PyNite and our own solver; not an engineering design. F1 passed the stress and movement checks, then failed the curl-root fit check. The slot-width rule changed before the final round; chart-reading notes and carbon scope are explained below.

Models

Ember Monolith · Structure search

From the modelRhino → PyNite, 15 variants + 1

Ask your AI assistant

Search for a timber frame inside the 0.8 m wall, round by round, and rank the passing ones by carbon.

Show the full prompt

Using the Archi Automate MCP, read the wall of the Rhino model [Ember Monolith] read-only: the [generating profiles], the slot edge, the entrance and the curl, and write them to a frozen dataset without changing or saving the document. Then, in Python outside Archi Automate, generate structural variants that fit inside the [0.8 m] wall without touching the shell, the curled entrance wall or the open slot: [glulam ribs, steel ribs, rings and braces]. Run each in [PyNite] and cross-check it with a second, independent solver; check stress, shear, deflection and sway against [Japanese allowable-stress] limits; rank the passing ones by [upfront carbon, A1-A3]. Fix each round's rules before it runs, and keep going round by round until a variant passes. Then render the frame of each round from one camera in Blender.

Not a transcript. The search ran over one working day as a series of rounds directed in conversation: a structure lead wrote the rules and the variants, other agents wrote and ran the generator, the engines and the checks, and a reviewer from another model family reviewed the rules and the code. This task restates that process. The structural numbers come from PyNite and a second solver run as Python, not from an Archi Automate tool. Values in [brackets] are yours to change.

AI agents searched for a timber frame inside the 0.8 m wall of an invented temple: 15 variants over three rounds and one comparison run, checked in PyNite and our own solver. Preliminary: F1 passed the stress and movement checks, then failed a fit check at the curl root; F2 is being prepared.

Archi sample model: an invented building on a real site in Shikoku, Japan. Not a built project.

Engine
Claude (orchestration, checks and graphics), Fable 5.2 (structure lead), gpt-6.1-sol through Codex (reviews). Structural numbers: PyNite 3.2.1 and our own solver. No image or video model.
Input
Rhino
Date
2026-11-22
Tools
Rhino → PyNite → Blender → rhino_run_readonly_csharp_probe → blender_run_write_task
MCP calls
rhino_run_readonly_csharp_probe → blender_run_write_task

Method notes

Preliminary study with PyNite and our own solver; not an engineering design. The Ember Monolith is an invented temple with a sculpted wall 0.8 m thick. This page shows how AI agents looked for a structure that fits inside that wall, with the shell, the curled entrance wall and the open rooflight slot left exactly as designed. The main image, a Blender render, shows the frame of each round from one camera.

The brief. The owner asked for a wood or steel structure inside the wall, chose the lowest upfront carbon as the aim, and allowed free tools only. Each round’s rules were fixed before it ran; the one rule changed afterwards, on the movement of the open slot, was changed by the owner, and that movement is now reported rather than checked.

Three rounds. The agents checked 15 variants over three rounds, plus one comparison run. In the first round, the worst value of each variant ran from 3.66 to 28.64 times its limit; in the second, from 1.61 to 2.46. In the final round one variant, F1, passed every gated check, at 0.96 of its limit (sway, 14.4 mm against 15.0 mm); the other two did not: H3F at 1.20 and H4F at 1.13.

Carbon. F1’s upfront carbon (product stage, A1-A3) is 239.6 t CO2e, or 74 %, lower than that of the steel-rib model HS. That is against that particular steel model, not against an optimised steel frame, which nobody looked for. Carbon stored in the timber is reported apart and never subtracted.

Where it stands. F1 passes the stress and movement checks; the fit at the curl root failed the solid check, so F2 is being prepared. Buckling, second-order effects, connections and foundations are still open.

Done outside Archi Automate. Through the Archi Automate MCP, an agent read the wall from the open Rhino model with rhino_run_readonly_csharp_probe, read-only, and left the document unchanged; another rendered the main image in Blender with blender_run_write_task. The generator, the two engines (PyNite 3.2.1 and our own solver), the checks, the ranking, the two charts and the section are Python that AI agents wrote and ran outside the product.

Reading the charts and the section. Chart 1 is on a log scale (1 = at the limit): round 1 compared six layouts with coarse, uniform starting sizes, all governed by horizontal sway; round 1b tested six refined frames, each governed by the change in width of the open roof slot, as then required; H3F and H4F are round 1b’s H3 and H4, rerun under the final rules. The slot-width rule (21 mm) was required in rounds 1 and 1b, which are shown as computed then; before the final round the owner made it report-only, because nothing spans the open slot. It was the only check the steel model HS failed in round 1b. Not drawn: G-strut, a round 1 comparison run that was never ranked (12.5, next to G1). Chart 2 shows one point for each of the 16 variants with a quantities file; some coincide, so 12 positions show (H3/H3F and H4/H4F differ by under 1 kg, G-strut sits on G1, H1 and H5 nearly coincide). Carbon covers the product stage (A1-A3, fossil) of the parts in the ranking, with their connector allowance, and mass covers the same parts; foundations, cladding, transport and erection, use and end of life are excluded, and stored biogenic carbon is reported, never subtracted. Circles have glulam ribs and squares steel ribs; filled points passed the gate, hollow ones did not. The points with less carbon than F1 all failed checks: H3/H3F (72.6 t), G2 (83.0 t) and H2 (84.2 t). HS is the steel model we compared against, not an optimised steel frame. Drawing 3 is a Python vector drawing, not a render: purlin rings 0.12 x 0.36 m and braces 0.12 x 0.12 m are cut, and the rib beyond, 0.28 x 0.54 m on one side and 0.20 x 0.54 m on the other, fills the 0.60 m zone with a few centimetres to spare. That clearance describes this cut only; it does not show that F1 fits throughout, and the fit check at the curl root failed.

More cases

All cases

Full size view