The glass as modelled

A: glass as modelled (assumed g 0.50, light transmission 0.70) · the south-east bays on the right a shade lighter than with the option

Captured from the Archi Automate viewer with its fast-mode tag, legend, labels and credits, in the same layout as the option above, so the two can be read side by side; both runs are fast. Daylight factor under the CIE overcast sky on the Level 3 work plane, from dark purple at 0 % to yellow at 20 % and more; project north up, the south-east facade on the right. Hatched patches are zone area without a work-plane sensor. The zones by the court that have no windows read dark: what light they show comes from the neighbouring bays, and they are left out of the daylight figures on this page. Early-stage facade-bay estimate (typical weather year, stated glazing and room assumptions). Not an energy calculation, a daylight verification or an overheating assessment.

Simulations

Zurich office · Lower-g glass on the south-east facade

From the modelRevit → glass option, quick look

In two fast runs on Level 3 of the Zurich office, lower-g glass (g 0.25, design-option values) on the south-east facade only cuts the estimated solar gain of the south-east bays from 134.5 to 78.2 kWh per m² of floor a year (−42 %), and their highest peak from 166 to 101 W/m². Their median daylight factor falls from 4.33 % to 3.12 %, but every south-east bay stays at or above the indicative EN 17037 minimum. The other facades do not change.

Good for a facade-by-facade glazing decision: the south-east is where a lower g pays, taking about 40 % of those bays' solar gain for about a quarter of their daylight factor. Only the south-east was changed here; whether another facade needs the same glass is a separate study. The glass as modelled is assumed. An estimate, not a cooling load: a cooling engineer still sizes the plant.

Ask your AI assistant

Compare lower-g glass on the south-east facade of the Zurich office with the glass as modelled.

Show the full prompt

Using the Archi Automate MCP, take the Revit scene of [the office] and the facade-bay analysis of [Level 3], with the glass as modelled with [g 0.50, light transmission 0.70]. Add a design option with [lower-g glass, g 0.25, light transmission 0.50, U 0.6] on [the exterior south-east panes only], check it with analysis_check, then run sim_facade in fast mode on both, the option compared with the glass as modelled, with the [Zurich typical-year weather file] and true north [62.8°]. Give me the solar gain, the peak and the daylight factor per facade for both, and show the Level 3 plan of each in the Archi Automate viewer.

Not a transcript. The study was run in a working session directed in conversation; this task restates it. Values in [brackets] are yours to change. The glass as modelled is an assumption made by the assistant; the lower-g values are design-option inputs, not a product. The option's glass rule was matched to the 206 exterior south-east panes by their Revit ids; the court's south-east-facing panes keep the glass as modelled.

Radiance compares daylight factor and solar gain for two glass options on Level 3 of the sample Zurich office, from Revit in fast mode. An early-stage estimate with assumed glass, not a cooling load; the gain screen was cut off, so gain figures come from numerical results.

Archi sample model, a Zurich office. Not a built project.

Engine
Claude (assistant). No image or video model; the colours are computed daylight factors.
Input
Revit
Time
sim_facade in fast mode, glass as modelled 1,179 s (about 20 min), option 360 s (6 min, reusing the first run's sun data), with another simulation running on the same PC
Date
2026-11-15
Tools
Revit → sim_facade → viewer_capture
MCP calls
revit_export_scene → analysis_check → sim_facade → ifc_job_status → viewer_show → viewer_set → viewer_capture

Archi Automate · Weather: climate.onebuilding.org TMYx (Lawrie, L.K. and Crawley, D.B. 2022) · Context: swissBUILDINGS3D 3.0, © swisstopo · Context: 22 neighbouring buildings surveyed for this sample model · Radiance (LBNL licence). Computed on an Archi Automate build that is not released yet, directed by Claude. No image or video model: the colours are computed daylight factors.

Method

Archi Automate output, unretouched. The image at the top is the option, B: lower-g glass on the south-east; the still below is A: the glass as modelled. Both are the Level 3 plan captured from the Archi Automate viewer with its own fast-mode tag, legend, labels, method notes and credits, coloured by the daylight factor under an overcast sky. The south-east facade is the right-hand side of the plan. The viewer cannot draw the difference between the two options, and its solar-gain screen of this pair was cut off at the bottom, so the solar-gain figures below come from the results, not from the pictures.

How it was made: the Revit scene of the office was split into glass, spandrel panels, structure and context in an analysis file, and Level 3 into 74 catchment zones behind the facade, with 164 windows. A, the glass as modelled, is assumed: g 0.50 and light transmission 0.70, with an internal roller blind that closes when more than 200 W/m² reaches the glass. B adds one glazing type, g 0.25, light transmission 0.50 and a glass U-value of 0.6 W/m²K, on the 206 exterior south-east panes only, on all levels; analysis_check confirmed that the rule matched those 206 panes and changed nothing else. sim_facade ran both in its fast mode (Quick preset) with Radiance and a typical weather year for Zurich, B with A as its comparison, which the tool accepts only when the zones and the mode are the same. A took about 20 minutes and B 6, reusing A’s sun data, while another simulation shared the PC.

What it gives for Level 3, per m² of floor, A to B:

  • The south-east bays (12 zones, 36 windows): solar gain 134.5 to 78.2 kWh a year (−42 %), May to September 68.2 to 39.6, the highest zone peak 166 to 101 W/m². The two corner bays with south-east glass: −24 % and −21 %.
  • Their daylight: median daylight factor 4.33 % to 3.12 % (−28 %), the corners −16 % and −10 %. All of the south-east bays’ floor stays at or above the indicative EN 17037 minimum, as does 79 % of the whole floor with either glass.
  • The other facades: north-east, south-west, north-west and the court gain the same; their daylight factor moves by −2 % to +1 %, within the fast mode’s noise.
  • The whole floor: 92.2 to 80.6 kWh a year (−13 %); the peak of the whole floor at once, 56.7 to 47.6 W/m², both on 21 March between 12:00 and 13:00 standard time, when the low spring sun is on the south-east glass.

Limits

  • Early-stage facade-bay estimate (typical weather year, stated glazing and room assumptions). Not an energy calculation, a daylight verification or an overheating assessment. Not a daylight verification for TEK17, BR18 or BFS 2024:8.
  • Solar gain is an estimate, not a cooling load.
  • Fast mode, as the tool labels it: “Fast assessment: Quick preset reads about 2 % low (room R1); zone medians and the 95 %-area daylight factor can differ by up to about 8 % from normal. Use normal for EN levels and reporting.” In fast mode the tool does not rank options closer than about 2 % in annual gain, and differences below its noise (8 % for zone medians, 3 % for means) are not read as changes. Both runs are fast; they are not compared with any normal run.
  • Catchment zones: values per m² of floor scale with the zone depth; options are compared at the same depth, as here.
  • The glass as modelled is assumed; the lower-g values are design-option inputs, not a product.
  • Room temperatures are withheld by the tool until its simplified room model passes the IEA BESTEST checks. The 10 windowless zones by the court read 0 % and are left out of the daylight figures.
  • This run used a build of Archi Automate that is not released yet, so the page is marked “In development”.

More cases

All cases

Full size view