1920 × 1080 px. Open it full size to see it at 100%.

Other views

From the north-east · about 409 kWh/m² a year on the north-east facade
From the south-west · clean plate, no legend

Captured from the Archi Automate viewer. Early-stage facade estimate (typical weather year, stated assumptions). Not an energy calculation or a compliance report. Incident radiation on the facade, not heat gain. Scale 0–1,250 kWh/m² per year. Archi Automate · Weather: climate.onebuilding.org TMYx (Lawrie, L.K. and Crawley, D.B. 2022) · Radiance (LBNL licence) · Context: swissBUILDINGS3D 3.0, © swisstopo · Context: 22 neighbouring buildings surveyed for this sample model.

Simulations

Zurich office · Facade solar radiation

From the modelRevit → facade solar radiation, Radiance

Over a typical weather year, the south-west facade of the Zurich office receives 732 kWh/m² of solar radiation on average and the south-east 668, against 409 on the north-east and 301 on the north-west. The roof receives 1,214 kWh/m², and the surrounding buildings shade the lower storeys.

That shows where the facade works hardest: which sides to study first for solar control or lower-g glass, and how much the roof receives. It measures radiation on the outside of the facade, not heat gain through the glass; an early-stage facade estimate, not an energy calculation or a compliance report.

Ask your AI assistant

Export the Zurich office from Revit and map a typical year's solar radiation on its facades.

Show the full prompt

Using the Archi Automate MCP, export the active Revit 3D view of [the office with its context masses] with revit_export_scene. Run sim_facade on that scene with the [Zurich typical-year weather file], a [1.5 m] grid and the [quick] preset, true north [62.8°], and treat the context masses as shading only. Show the yearly incident solar radiation on the facades in the Archi Automate viewer from [the south-west] and [the north-east], and give me the area-weighted mean per orientation.

Not a transcript. The study was run in one working session directed in conversation; this task restates it. Values in [brackets] are yours to change. The scene reported grid north (62.0°), so the assistant passed true north, 62.8°, to sim_facade. The weather file was downloaded from climate.onebuilding.org beforehand.

Radiance maps annual incident solar radiation on the sample Zurich office's facades and roof from Revit, shown in the Archi Automate viewer. An early-stage estimate with maximum-height context blocks and no trees; outside radiation, not heat gain through glass.

Archi sample model, a Zurich office. Not a built project.

Engine
Claude (assistant). No image or video model; the colours are computed radiation.
Input
Revit
Time
sim_facade 1,555 s (about 26 min, with other simulations running on the same PC)
Date
2026-11-14
Tools
Revit → sim_facade → viewer_capture
MCP calls
revit_export_scene → analysis_inventory → sim_facade → ifc_job_status → viewer_show → viewer_set → viewer_capture

Archi Automate · Weather: climate.onebuilding.org TMYx (Lawrie, L.K. and Crawley, D.B. 2022) · Radiance (LBNL licence) · Context: swissBUILDINGS3D 3.0, © swisstopo · Context: 22 neighbouring buildings surveyed for this sample model. Computed on an Archi Automate build that is not released yet, directed by Claude. No image or video model: the colours are computed radiation.

Method

Archi Automate output, unretouched. The main image is a capture from the Archi Automate viewer; the title, legend, method note, north arrow and credits are drawn by the viewer. Its subtitle (“Perspective from the south-west”) was set by the assistant, because the viewer would have called this high view “eye level”. The swisstopo credit is not on the frame and is given here.

How it was made: revit_export_scene exported the active Revit 3D view: the office envelope, curtain panels, structure and the 141 context masses, 3,329 elements in all. sim_facade then ran Radiance with a typical weather year for Zurich on 8,648 points, one per 1.5 m facade cell, with the quick preset. The context masses only shade; they are not analysed. It took about 26 minutes while other simulations shared the PC.

Area-weighted means of the incident radiation per year: south-west 732 kWh/m², south-east 668, north-east 409, north-west 301. From May to September: south-west 411, south-east 350, north-east 271, north-west 187. The roof receives 1,214 kWh/m² a year.

Limits

  • Early-stage facade estimate (typical weather year, stated assumptions). Not an energy calculation or a compliance report.
  • Incident radiation on the outside of the facade, not heat gain through the glass. For gain behind the glass see “Zurich office · Daylight and solar gain behind the facade”.
  • A typical weather year, not a hot summer. Surface reflectance 0.35; the glazing is not classified in this run.
  • Surrounding buildings are simple blocks at their maximum roof height; trees are not modelled.
  • This run used a build of Archi Automate that is not released yet, so the page is marked “In development”.