1920 × 1080 px. Open it full size to see it at 100%.

Other views

Level 3 from the north-east · about half the gain of the south-east bays

Captured from the Archi Automate viewer, without legend (clean plate). The studied storey's glazing is coloured by the estimated solar gain through the glass, May to September: yellow = highest, magenta = lower. Early-stage facade-bay estimate (typical weather year, stated glazing and room assumptions). Not an energy calculation, a daylight verification or an overheating assessment. Archi Automate · Weather: climate.onebuilding.org TMYx (Lawrie, L.K. and Crawley, D.B. 2022) · Radiance (LBNL licence) · Context: swissBUILDINGS3D 3.0, © swisstopo · Context: 22 neighbouring buildings surveyed for this sample model.

Simulations

Zurich office · Daylight and solar gain behind the facade

From the modelRevit → facade-bay estimate, Radiance

On Level 3 of the Zurich office, with assumed glass (g 0.50), the south-east bays take the most solar gain, 114 kWh per m² of floor a year, the north-west 55. In a separate fast run of the 15 enclosed rooms, the corner Focus Room 3.18 stands out at 338 kWh/m² a year and a median daylight factor of 15 %, a room to check for heat and glare. In two further fast runs, lower-g glass (g 0.25) cut the estimated gain by 44 % against the assumed glass, for 29 % less daylight.

Good for choosing glass and shading per side before an energy consultant joins, and for finding the rooms to look at first. An early-stage facade-bay estimate, not an energy calculation, a daylight verification or an overheating assessment; glare and room temperatures are not shown, and glass properties are assumed.

Ask your AI assistant

Study one storey of the Zurich office bay by bay: solar gain through the glass and daylight in each zone.

Show the full prompt

Using the Archi Automate MCP, take the Revit scene of [the office] and run a facade-bay study with sim_facade on [Level 3]: catchment zones behind the facade, the glazing as modelled with [triple glazing, g 0.50, light transmission 0.70] and [internal roller blinds that close above 200 W/m²], the [Zurich typical-year weather file] and true north [62.8°]. Check the analysis file with analysis_check first. Give me the solar gain and the daylight factor per orientation, and show the storey in the Archi Automate viewer from [the south-west] and [the north-east].

Not a transcript. The study was run in one working session directed in conversation; this task restates it. Values in [brackets] are yours to change. The glass values are assumptions made by the assistant: the Revit panel type carries no optical values. The analysis file that tells sim_facade which panels are glass, spandrel, structure and context was written by a script the assistant ran outside Archi Automate, then checked with analysis_check.

Archi Automate computes daylight factor and solar gain bay by bay on Level 3 of the sample Zurich office from Revit with Radiance. An early-stage estimate with assumed glass; room temperatures are withheld by the tool.

Archi sample model, a Zurich office. Not a built project.

Engine
Claude (assistant). No image or video model; the colours are computed solar gain.
Input
Revit
Time
sim_facade 1,306 s (about 22 min, with other simulations running on the same PC); Level 3 rooms study, fast mode, 1,397 s (about 23 min, also on a shared PC); Level 3 glass options, assumed glass and lower-g glass (g 0.25), both fast mode, about 35 and 21 min (shared PC)
Date
2026-11-14
Tools
Revit → sim_facade → viewer_capture
MCP calls
revit_export_scene → analysis_check → sim_facade → ifc_job_status → viewer_show → viewer_set → viewer_capture

Archi Automate · Weather: climate.onebuilding.org TMYx (Lawrie, L.K. and Crawley, D.B. 2022) · Radiance (LBNL licence) · Context: swissBUILDINGS3D 3.0, © swisstopo · Context: 22 neighbouring buildings surveyed for this sample model. Computed on an Archi Automate build that is not released yet, directed by Claude. No image or video model: the colours are computed solar gain.

Method

Archi Automate output, unretouched. The images are clean plates from the Archi Automate viewer: Level 3’s glazing is coloured by the viewer’s default Gain screen, the estimated solar gain through the glass from May to September; the rest of the building is grey. The viewer’s Daylight, Comfort and Glare screens and the Level 3 plan could not be captured in this first run; the daylight figures below come from the study’s results. A later, separate study of the Level 3 rooms is shown at the end of this section.

How it was made: the Revit scene of the office was split into glass, spandrel panels, glulam structure and context masses in an analysis file, and Level 3 was divided into 74 catchment zones behind the facade (EN 15193 depth, 4.5 to 6 m, 3.6 m bays), 1,377 m² of floor with 164 windows. The glass is assumed: triple glazing with g 0.50 and light transmission 0.70, with internal roller blinds that close when more than 200 W/m² reaches the glass. sim_facade ran Radiance with a typical weather year for Zurich; it took about 22 minutes while other simulations shared the PC.

What it gives for Level 3: solar gain through the glass of 91.7 kWh per m² of floor a year, 52.8 from May to September. By orientation, per year: south-east 114, south-west 87, north-east 56, north-west 55 kWh per m² of floor. Daylight factor under an overcast sky, median per zone, area-weighted mean 5.3 % (10th percentile 3.0 %, 90th percentile 9.1 %); 87 % of the floor lies in zones at or above the indicative EN 17037 minimum, as an indication, not a verification.

Level 3 rooms, daylight: a second, separate study in fast mode. On a later development build, sim_facade ran again in its fast mode (Quick preset) on the Revit scene, this time with the 15 enclosed rooms on Level 3 as the zones: focus, meeting, project and quiet rooms, stairs and WCs, 233.9 m² of floor with 27 windows. The open-plan offices are not part of it and stay blank in the plan. Daylight factor under an overcast sky, median per room, floor-weighted mean 3.5 %; 59 % of the studied floor lies in rooms at or above the indicative EN 17037 minimum. Rooms without windows read 0 % and count in the floor. The zones, the scene and the mode differ from the study above, so the two sets of figures are not compared.

Level 3 rooms, daylight factor under the CIE overcast sky, captured from the Archi Automate viewer with its legend and credits. The open-plan floor is left blank; the legend runs from 0 % in dark purple to 20 % and more in yellow, beside the indicative EN 17037 table and method notes. Fast assessment: Quick preset reads about 2 % low (room R1); zone medians and the 95 %-area daylight factor can differ by up to about 8 % from normal. Use normal for EN levels and reporting. Early-stage facade-bay estimate (typical weather year, stated glazing and room assumptions: light transmission 0.70 assumed, blinds open, no furniture). Not a daylight verification.

Limits

  • Early-stage facade-bay estimate (typical weather year, stated glazing and room assumptions). Not an energy calculation, a daylight verification or an overheating assessment.
  • Solar gain is the radiation on the glass × angle-dependent g-value × glass area, with blinds closed above 200 W/m²; not a cooling load. Blind figures are indicative.
  • Catchment zones: values per m² of floor scale with the zone depth; compare options only at the same depth.
  • Room temperatures are withheld by the tool until its simplified room model passes the IEA BESTEST checks. Glare was not computed for the whole storey.
  • This run used a build of Archi Automate that is not released yet, so the page is marked “In development”.
  • The separate enclosed-room fast run excludes open-plan offices, counts windowless rooms at zero and uses different zones, scene and mode: do not compare it with the facade-bay run.

More cases

All cases

Full size view