Workflow · Quantities and carbon
EPD attach
Find an ÖKOBAUDAT EPD for each material in an IFC model and write it onto the file, so the next tool reads the carbon factors offline. On the Zurich office, an Archi sample model, 4 materials matched, 79 % of the volume, and the saved file gave the live lookup's 2,609.9 t CO2e.
4 materials carry an ÖKOBAUDAT EPD in the saved IFC · Zurich office
2,609.9 t CO2e A1-A3 from the saved file, offline, as with the live lookup
79 % of the volume covered, 4,676.8 of 5,924 m³
12.3 s offline estimate from the saved file
What was checked
Every material in the model was looked up in ÖKOBAUDAT. Four matched: two concretes (Beton der Druckfestigkeitsklasse C25/30, 181 kg CO2e/m³), screed (Zementestrich, 444.34 kg CO2e/m³) and anodised aluminium (Aluminiumprofil pressblank, 5,215.14 kg CO2e/m³). No match: glass, glulam, partitions, door parts and unnamed materials, which stay on generic factors. Written per material: EPD source, UUID, URI and GWP A1-A3 per m³, an ISO 22057-aligned subset, not a full EPD.
4 materials with an EPD · ÖKOBAUDAT EPDs written onto the IFC materials as Pset_EnvironmentalImpactValues
Steps, as the assistant ran them
- ifc_attach_epd
Looked up every material and wrote an ÖKOBAUDAT EPD onto the four that matched, as Pset_EnvironmentalImpactValues.
- ifc_save
Saved the enriched model as a new 32.1 MB IFC; the input was not overwritten.
- ifc_open
Opened the saved copy, to prove the EPDs travel with the file.
- ifc_job_submit
Ran carbon_estimate on the saved copy with no EPD source, offline: the three EPD materials read as model-attached EPDs, 2,609.9 t CO2e for A1-A3, 288 kg/m², in 12.3 s.
Tool chain
ifc_attach_epd → ifc_save → ifc_open → ifc_job_submit
Programs in this workflow
- IFC · The open IFC model the tools read, check and write
- Quantities and carbon · Computes quantities and embodied carbon from the IFC
Method
The assistant asked Archi Automate to find an EPD for every material in the Zurich office IFC. Four materials matched an ÖKOBAUDAT EN 15804+A2 dataset: the two concretes, the screed and the anodised aluminium. Each EPD was written onto its IFC material as a property set with its source, UUID, link and GWP A1-A3 per m³, and the model was saved as a new file.
To prove the EPDs travel with the file, the saved copy was opened again and estimated with no online lookup. The three EPD materials were read from the model, and the result was the same as the live ÖKOBAUDAT run: 2,609.9 t CO2e for A1-A3, 288 kg CO2e/m² over 9,061.6 m².
Limits
- An ISO 22057-aligned subset (identity and GWP A1-A3 per m³), not a full EPD.
- The aluminium EPD (“pressblank” extrusion, about 1.9 kg CO2e/kg) is the tool’s first match; a person should choose the dataset for anodised curtain-wall profiles before the figure is used.
- The EPDs cover 4,676.8 m³, 79 % of the 5,924 m³ building volume; glass and timber stay on generic factors.
- Early-stage EN 15978 screening estimate, not a certified LCA.
- The recorded run used an Archi Automate development build; the tools it calls are in the released version.
- The Zurich office is an Archi sample model, not a built project.